We are getting a new 95 efficient gas furnace and it has been mentioned that there are two options for venting it out of the walk in unfinished basement.
Can you vent a gas furnace through a wall.
The exhaust system typically uses metal venting often routed into a chimney stack to exhaust the combustion gases created in the furnace fire chamber.
Direct vent chimneys fireplaces.
You need to use an auxiliary power inducer.
Guide to choosing installing troubleshooting through wall or side wall venting exhaust devices for heating appliances like oil or gas fired boilers furnaces or water heaters photos examples of sidewall venting or direct venting installations that are improper and or.
Type b vent pipe.
The answer is yes and no an 80 efficient furnace can be side wall vented per national fuel as code 7 3 4 with the use of a mechanical draft system of either forced or induced draft design.
Louis area home contact jerry kelly your st.
If you have any questions about whether your furnace flue pipe should go through the roof or the side of the house or if you d like a furnace installed in your st.
It could either go out the unused walled in chimney that the oil furnace was vented through or they could cut a hole in the concrete block wall and vent it out the side of the house.
Sidewall vent direct vent direct exhaust systems for oil or gas fired heaters.
A conventional natural gas furnace will vent the dangerous combustion gases through a simple vertical exhaust system that is attached to the furnace.
You can vent anything out the wall there just needs to be an inducer motor to be sure the exposed vent on the interior of the home stays in a negative pressure.
Well making sure that you choose the right venting style will protect them.
Be sure to check the clearance distances required for your particular heater brand and model.
The wall mount direct vent gas furnace exhaust vent outdoor clearance distances shown in our illustration below are an example adapated from williams 2018.
The efficiency rating of a furnace is called afue annual fuel utilization efficiency.
The condition of the chimney is a factor because new super efficient gas furnaces do not vent up the chimney they are vented outdoors horizontally through a wall by a small plastic pipe.
You cannot just take the vent off an 80 efficient furnace and run it out a side wall.
So what does this mean.
The inducer motor mimics the negitive pressure of a flue effect on a proper verticle chimney to a horozontal flue vent.
Read more elaboration about it is given here in respect to this can a high efficiency furnace vent through a chimney.
A gas wall heater or older forced air furnace generally requires a type b double wall metal vent pipe while a new high efficiency furnace requires a schedule 40 pvc vent pipe.
Louis furnace repair and installation contractor.